Running but not cooling
If the compressor runs and the cabinet stays warm, the usual suspects are a refrigerant leak, a blocked or dirty condenser, a failing compressor, or a restriction in the capillary tube. A leak will not fix itself and topping up gas without finding the leak only buys time.
Feel the condenser (usually the black grid on the back or the coil underneath). If it is barely warm while the compressor runs continuously, the system is not rejecting heat properly and needs testing with gauges.
Icing up
Ice on the evaporator in a frost-free fridge usually means a defrost fault: a failed heater, a defrost timer or sensor, or a blocked drain that lets water refreeze. In a chest freezer, heavy ice usually points to a tired lid seal letting damp air in, or a lid that is not closing squarely.
Do not chip ice off with a knife. You will puncture the evaporator and turn a small repair into a sealed-system repair.
Water inside or underneath
A blocked defrost drain is the most common cause of water pooling at the bottom of a fridge. In coastal homes, humidity makes more condensate, so a partially blocked drain shows up sooner. If the water is under the unit rather than inside, check the drain pan and the door seal before assuming the worst.
Clicking, humming or tripping
Repeated clicking with no start often points at the start relay, capacitor or compressor. A compressor that hums and trips the breaker is an electrical fault that should be tested rather than reset repeatedly. In coastal installations, corroded terminals are a realistic contributor and worth inspecting at the same time.
In short
- Running without cooling usually means a sealed-system or condenser problem
- Ice build-up is normally a defrost fault or a door seal
- Never chip ice off an evaporator
- Repeated clicking or tripping needs testing, not resetting
Related services